{"product_id":"gas-clip-single-gas-clip-plus","title":"Gas Clip Single Gas Clip Plus","description":"\u003cp\u003e• Hibernate Mode - every minute rested is a minute saved of life • Unmatched sensor reliability for H2 S or CO • Adjustable alarm set points \u0026amp; real-time gas reading capability • 0.1 ppm resolution for H2 S sensor and display • Two-way IR comms for event downloads, bump tests \u0026amp; updates • Simple to use one button operation • “Bump Check” confirmation\/identification • No hidden service charges or maintenance fees • Lightweight \u0026amp; durable - clamps on tight with alligator clip\u003c\/p\u003e\n\u003ch5\u003eGas Clip Technologies Single Gas Clip PLUS; H₂S or CO\u003c\/h5\u003e\n\u003cdiv class=\"blurb\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cimg title=\"\" alt=\"\" src=\"https:\/\/www.baselineequipment.com\/shop\/wpimages\/1486677850-assembled-in-usa-gasclip.jpg?width=700\"\u003eGas Clip Technologies Single Gas Clip Plus or SGC Plus, is the only maintenance free handheld gas detector available with “Hibernate” mode. \u003c\/li\u003e\n\u003cli\u003e“Hibernate” mode allows users to place this disposable single gas detector in a rested state when not in use. \u003c\/li\u003e\n\u003cli\u003eThe SGC Plus is perfect for seasonal\/turnaround contractors or rental fleets. \u003c\/li\u003e\n\u003cli\u003eWhen your job or turnaround is finished, simply synchronize the instrument with our IR Link or SGC Dock and put the detector in a rested state. \u003c\/li\u003e\n\u003cli\u003eWhen you are ready to use the detector again, simply press the power button to reactivate the detector\u003c\/li\u003e\n\u003cli\u003eWith the SGC Plus, you only pay for the time that the handheld gas detector is in use. \u003c\/li\u003e\n\u003cli\u003eEach SGC Plus will last for 24 months of use and comes with a warranty of 24 months of use or 3 years from activation (whichever comes first). \u003c\/li\u003e\n\u003cli\u003eHowever, this mode (Hibernate) can only be enabled via IR communication with either the\u003cspan\u003e \u003c\/span\u003eIR Link\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003eSGC Dock\u003cspan\u003e \u003c\/span\u003eaccessories (not by a button push), so only authorized personnel can place the units in “hibernate” mode. \u003c\/li\u003e\n\u003cli\u003eThe SGC Plus also provides the most advanced maintenance free disposable single gas detector on the market. \u003c\/li\u003e\n\u003cli\u003eUnlike other disposable single gas detectors, the SGC Plus combines a rugged design and reliability with advanced sensor resolution (0.1 ppm for H2S models). \u003c\/li\u003e\n\u003cli\u003eAdvanced micro processing capabilities allow for quick unit configuration adjustments to comply with current and future industrial health and safety gas exposure regulations for workers in industrial environments. \u003c\/li\u003e\n\u003cli\u003eEach SGC Plus comes with the following features: \n\u003cul\u003e\n\u003cli\u003eUnmatched sensor reliability for H₂S and CO \u003c\/li\u003e\n\u003cli\u003e“Hibernate” mode \u003c\/li\u003e\n\u003cli\u003eAdjustable alarm set points \u003c\/li\u003e\n\u003cli\u003eReal-time gas reading capability \u003c\/li\u003e\n\u003cli\u003e0.1 ppm resolution for H2S sensor and display \u003c\/li\u003e\n\u003cli\u003eTwo-way IR communication for event downloads, bump tests, unit configuration and firmware updates \u003c\/li\u003e\n\u003cli\u003eProgrammable unique 6 digit detector identification \u003c\/li\u003e\n\u003cli\u003e“Bump Check” confirmation\/identification \u003c\/li\u003e\n\u003cli\u003eOptional calibration \u003c\/li\u003e\n\u003cli\u003eCalibration confirmation\/identification \u003c\/li\u003e\n\u003cli\u003eDocking capability with Gas Clip Technologies SGC Dock \u003c\/li\u003e\n\u003cli\u003eModel numbers: SGC-P-H (H2S) or SGC-P-C (CO)\u003c\/li\u003e\n\u003cli\u003eBe sure to compare these features to our\u003cspan\u003e \u003c\/span\u003eMulti Gas Clip\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003eSingle Gas Clip\u003cspan\u003e \u003c\/span\u003eto find the right product for your current application. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eFeatures:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBump Check Reminder: \u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eAll Single Gas Clip models come standard with the bump check reminder feature. \u003c\/li\u003e\n\u003cli\u003eWhen activated, if the detector has not been bump tested within the designated interval, the instrument will emit both a flash and show “buP” across the screen alerting the user, peer, or supervisor that the gas bump test is due. \u003c\/li\u003e\n\u003cli\u003eIn addition to the flash, the TEST Icon will continually display in the upper left hand corner. \u003c\/li\u003e\n\u003cli\u003eThis alert increases user accountability and allows for easier policy enforcement. \u003c\/li\u003e\n\u003cli\u003eNote the flash feature can be disabled within the IR Link software, if desired.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable unique 6 digit ID: \u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eConsidering the rugged environment these instruments are often exposed to and used in, identification via serial number, sticker, or marker can be unreliable. \u003c\/li\u003e\n\u003cli\u003eWith the unique ID feature, units can be identified with a simple push of a button. \u003c\/li\u003e\n\u003cli\u003eAvailable using both limited alpha and full numeric characters, each unit can be assigned a unique ID utilizing, for example an employee ID number, last 4 digits of SSN, or a job code. \u003c\/li\u003e\n\u003cli\u003eUnique ID’s will also appear on event log reports and bump test logs. \u003c\/li\u003e\n\u003cli\u003eID’s will be displayed on the detector screen in segments of 3 digits at a time (first 3 digits, then last 3 digits). \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable alarm set points: \u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eTo adapt with changing health and safety gas exposure regulations for workers in industrial environments , the Single Gas Clip alarm set points can be easily adjusted via the\u003cspan\u003e \u003c\/span\u003eIR Link\u003cspan\u003e \u003c\/span\u003esoftware or through the\u003cspan\u003e \u003c\/span\u003eSGC Dock. \u003c\/li\u003e\n\u003cli\u003eDetectors can also be special ordered with custom alarm set points. \u003c\/li\u003e\n\u003cli\u003ePlease contact your Gas Clip Technologies representative for more information.\u003c\/li\u003e\n\u003cli\u003eUse the\u003cspan\u003e \u003c\/span\u003eContact Us\u003cspan\u003e \u003c\/span\u003epage or call 877-844-3101 to order units with custom Alarm Set Points or for bulk pricing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eOption Details:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eH2S (Hydrogen Sulfide) Measuring range: 0-100 ppm, Low alarm limit: 10 ppm, High alarm limit: 15 ppm*\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Gas Clip","offers":[{"title":"Hydrogen Sulfide","offer_id":49043986186430,"sku":"kha1789616714447","price":94.9,"currency_code":"USD","in_stock":true},{"title":"Carbon monoxide","offer_id":49043986219198,"sku":"dws1789616714448","price":105.12,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1826\/8862\/files\/gas-clip-single-gas-clip-plus_1.jpg?v=1789616718","url":"https:\/\/lanestep.shop\/products\/gas-clip-single-gas-clip-plus","provider":"My Store","version":"1.0","type":"link"}